ODM industrial panel PC · 12.5″ Full HD · 6 isolated RS485 · BMS / MODBUS
CTN-1262D Six Isolated RS485 Ports and Dry Contacts, 12.5-inch Panel PC
12.5″ 1920 × 1080 · IP65 front · 2× Intel LAN · 2.9 kg
Six isolated RS-485 ports and dry contacts, in one panel. The CTN-1262D is built for air-conditioning control rooms and environmental monitoring, where each chiller, AHU, meter and sensor sits on its own RS-485 trunk and half of what you watch is a contact rather than a value. It carries 6× electrically isolated RS485 ports, 1× isolated RS232, 4 dry-contact inputs and 2 dry-contact outputs, two USB 2.0 ports, audio, two Intel I210 LAN ports and a MODBUS interface that joins the existing BMS as another node — behind a 12.5-inch 1920 × 1080 IP65 front and inside a 264.9 × 184.0 mm cutout.

6× isolated RS4851× isolated RS2324 DI + 2 DO dry contactsMODBUS / BMS12.5″ 1920 × 1080IP65 front · fanless
17+
Years
50+
Countries
1
MOQ unit
2–4
Weeks lead
OEM
ODM & branding
At a glance
CTN-1262D key specifications
The panel, the touchscreen, the compute, the ports and the mechanical fit — everything that decides whether this panel drops into your cutout.
Panel size
12.5″ 16:9
Resolution
1920 × 1080
Brightness
300 cd/m² · 500:1
Touch
Multi-touch P-CAP
Processor
Intel® Celeron® J1900 (J6412 / 12th Gen optional)
Memory
4–8GB DDR3L
Storage
1× mSATA SSD
RS485
6× isolated RS485
Dry contacts
4 DI + 2 DO
Ethernet
2× Intel I210 Gigabit LAN
RS232
1× isolated RS232
Protection
IP65 · fanless
Design notes
Why six isolated RS-485 ports belong in an air-conditioning panel

Six RS-485 buses on one panel, all isolated
An air-conditioning or environmental control room is a room full of separate buses: chillers, AHUs, VAV boxes, meters, sensors and the BMS gateway — each on its own RS-485 trunk. The CTN-1262D carries 6× isolated RS485 ports on DB9, so six trunks are polled from one panel instead of being merged and re-addressed. Isolation is the part that matters in that environment: a ground-potential difference between two buildings or two risers is what destroys a non-isolated port, and every one of the six ports here is isolated.
- 6× isolated RS485 ports on DB9 — six independent buses
- Isolation protects the panel from ground loops between risers
- No external converter or repeater per trunk
- 2× Intel I210 Gigabit LAN for the building and management networks
- One panel replaces a PLC rack plus a gateway in the riser cupboard
Dry contacts, because half of what you monitor is a switch
A large part of building automation is not data at all — it is a contact: a float switch, a fan-proof contact, a filter alarm, a door contact, a pump run-status relay. The CTN-1262D provides 4 dry-contact inputs and 2 dry-contact outputs, so those signals are wired directly into the panel rather than through an I/O module on the bus. The outputs drive the usual annunciators and interlocks, and because the whole set is exposed over MODBUS, an existing BMS or SCADA master reads and writes it as another node.
- 4 dry-contact inputs — float, fan-proof, filter and door contacts
- 2 dry-contact outputs for annunciators and interlocks
- MODBUS interface — joins an existing BMS or SCADA as a node
- Signals land on terminal blocks, not on a separate I/O card
- Designed for air-conditioning control rooms and environmental monitoring


A 12.5-inch panel that fits the cupboard
The display is a 12.5-inch 16:9 panel at 1920 × 1080, 300 cd/m² at 500:1 with a 50,000-hour LED backlight and projected-capacitive touch behind an IP65 front bezel. The chassis measures 313.9 × 199.8 × 87 mm with a cutout of 264.9 × 184.0 mm and weighs 2.9 kg: fanless, so nothing to clean and nothing to seize, which matters in a plant room that is rarely visited. It runs on 12V DC with 9–36V optional.
- 1920 × 1080 at 300 cd/m², 500:1, backlight 50,000 h
- 313.9 × 199.8 × 87 mm, cutout 264.9 × 184.0 mm, 2.9 kg
- IP65 front, fanless — no filter to service
- 12V DC (9–36V optional), AT / ATX startup
- Platform ladder: Celeron J1900 → 12th Gen Core in the same cutout
Configurations
Choose the CTN-1262D configuration
Three factory builds on one panel. The display, the touchscreen, the ports, the cutout and the mounting are identical across all three — only the processor and the standard memory change.

Intel® Celeron® J1900
Standard · Celeron J1900
Best forBuilding-automation and air-conditioning control rooms where the panel polls six RS-485 buses and reports to a BMS — the standard build, at 10 W TDP.
Part number C11.01.04.014 — standard build: 4GB memory, mSATA SSD 128GB.
System core
| Processor | Intel® Celeron® J1900 |
| Memory | 4GB (4–8GB DDR3L on the J1900 build) |
| Storage | mSATA SSD 128GB |
| Storage slots | 1× mSATA SSD |
| Cooling | Fanless — no fan, no filter |
| Operating system | Windows 10 / 11 · Linux Ubuntu 16.04–22.04 |
Panel & touch
| Panel size | 12.5-inch TFT LCD, 16:9 |
| Max. resolution | 1920 × 1080 |
| Brightness | 300 cd/m² |
| Contrast | 500 : 1 |
| Backlight | LED, 50,000 hours |
| Touch panel | Projected capacitive touch (resistive 5-wire optional) |
| Front protection | Front panel IP65 compliant |
I/O & networking
| RS485 | 6× RS485 communication ports, all electrically isolated |
| RS232 | 1× isolated RS232 port |
| Dry contact input | 4 dry-contact input channels — external switch-signal acquisition |
| Dry contact output | 2 dry-contact output channels — switch-signal control |
| USB | 2× USB 2.0 (Type-A) |
| Ethernet | 2× 10/100/1000M Intel I210 Gigabit LAN |
| Audio | 1× audio, 3.5 mm TRRS · 2× loudspeaker |
| Expansion | 1× Mini PCIe socket |
Expansion & wireless
| Wireless network | 4G LTE full netcom module (optional) |
| Wi-Fi | Intel N6235 300 Mbps, 802.11a/b/g/n, 2.4G / 5G · Bluetooth |
| Clear CMOS | 1× Clear CMOS switch |
Power
| DC input | 1× 3-pin pluggable terminal block, 12V DC (9–36V DC optional) |
| Booting | 1× AT/ATX mode switch (internal) |
Environmental
| Operating temperature | 0–50 ℃ (−40–70 ℃ optional) |
| Storage temperature | −10–60 ℃ |
| Relative humidity | 10%–90%, non-condensing |
| EMC | CE, FCC (EN 55032 & EN 55035), EN IEC 61000-3-2 |
| Factory | ISO 9001:2015 |
| MTBF | 60,000 hours |
Mechanical & compliance
| Dimension | 313.9 (W) × 199.8 (D) × 87 (H) mm |
| Cutout size | 264.9 × 184.0 mm |
| Weight | 2.9 KG G.W. |
| Material | 6063 high-strength aluminium alloy |
| Construction | Aluminium extrusion + sheet metal |
| Mounting | Wall mount / VESA mount |
| Certifications | CE / FCC, according to EN 55032 & EN 55035 |
| ODM | BIOS / Boot on LOGO / OEM |

Intel® Celeron® J6412
Platform option · Celeron J6412
Best forCurrent Windows 10 / 11 installations that want DDR4 and a newer Celeron without moving to Core-class power.
Part number C11.01.04.015 — standard build: 8GB memory, mSATA SSD 256GB.
System core
| Processor | Intel® Celeron® J6412 |
| Memory | 8GB (DDR4 on the J6412 build) |
| Storage | mSATA SSD 256GB |
| Storage slots | 1× mSATA SSD |
| Cooling | Fanless — no fan, no filter |
| Operating system | Windows 10 / 11 · Linux Ubuntu 16.04–22.04 |
Panel & touch
| Panel size | 12.5-inch TFT LCD, 16:9 |
| Max. resolution | 1920 × 1080 |
| Brightness | 300 cd/m² |
| Contrast | 500 : 1 |
| Backlight | LED, 50,000 hours |
| Touch panel | Projected capacitive touch (resistive 5-wire optional) |
| Front protection | Front panel IP65 compliant |
I/O & networking
| RS485 | 6× RS485 communication ports, all electrically isolated |
| RS232 | 1× isolated RS232 port |
| Dry contact input | 4 dry-contact input channels — external switch-signal acquisition |
| Dry contact output | 2 dry-contact output channels — switch-signal control |
| USB | 2× USB 2.0 (Type-A) |
| Ethernet | 2× 10/100/1000M Intel I210 Gigabit LAN |
| Audio | 1× audio, 3.5 mm TRRS · 2× loudspeaker |
| Expansion | 1× Mini PCIe socket |
Expansion & wireless
| Wireless network | 4G LTE full netcom module (optional) |
| Wi-Fi | Intel N6235 300 Mbps, 802.11a/b/g/n, 2.4G / 5G · Bluetooth |
| Clear CMOS | 1× Clear CMOS switch |
Power
| DC input | 1× 3-pin pluggable terminal block, 12V DC (9–36V DC optional) |
| Booting | 1× AT/ATX mode switch (internal) |
Environmental
| Operating temperature | 0–50 ℃ (−40–70 ℃ optional) |
| Storage temperature | −10–60 ℃ |
| Relative humidity | 10%–90%, non-condensing |
| EMC | CE, FCC (EN 55032 & EN 55035), EN IEC 61000-3-2 |
| Factory | ISO 9001:2015 |
| MTBF | 60,000 hours |
Mechanical & compliance
| Dimension | 313.9 (W) × 199.8 (D) × 87 (H) mm |
| Cutout size | 264.9 × 184.0 mm |
| Weight | 2.9 KG G.W. |
| Material | 6063 high-strength aluminium alloy |
| Construction | Aluminium extrusion + sheet metal |
| Mounting | Wall mount / VESA mount |
| Certifications | CE / FCC, according to EN 55032 & EN 55035 |
| ODM | BIOS / Boot on LOGO / OEM |

Intel® Core™ i3-1215U
Platform option · 12th Gen Core
Best forSites that also log, trend or run a local database on the panel, where the 12th Gen platform and DDR5 pay for themselves in the same cutout.
Part number C11.01.04.016 — standard build: 8GB memory, M.2 SSD 256GB.
System core
| Processor | Intel® Core™ i3-1215U |
| Memory | 8GB (8–32GB DDR5 on the 12th Gen build) |
| Storage | M.2 SSD 256GB |
| Storage slots | 2× M.2 SSD |
| Cooling | Fanless — no fan, no filter |
| Operating system | Windows 10 / 11 · Linux Ubuntu 16.04–22.04 |
Panel & touch
| Panel size | 12.5-inch TFT LCD, 16:9 |
| Max. resolution | 1920 × 1080 |
| Brightness | 300 cd/m² |
| Contrast | 500 : 1 |
| Backlight | LED, 50,000 hours |
| Touch panel | Projected capacitive touch (resistive 5-wire optional) |
| Front protection | Front panel IP65 compliant |
I/O & networking
| RS485 | 6× RS485 communication ports, all electrically isolated |
| RS232 | 1× isolated RS232 port |
| Dry contact input | 4 dry-contact input channels — external switch-signal acquisition |
| Dry contact output | 2 dry-contact output channels — switch-signal control |
| USB | 2× USB 2.0 (Type-A) |
| Ethernet | 2× 10/100/1000M Intel I210 Gigabit LAN |
| Audio | 1× audio, 3.5 mm TRRS · 2× loudspeaker |
| Expansion | 1× Mini PCIe socket |
Expansion & wireless
| Wireless network | 4G LTE full netcom module (optional) |
| Wi-Fi | Intel N6235 300 Mbps, 802.11a/b/g/n, 2.4G / 5G · Bluetooth |
| Clear CMOS | 1× Clear CMOS switch |
Power
| DC input | 1× 3-pin pluggable terminal block, 12V DC (9–36V DC optional) |
| Booting | 1× AT/ATX mode switch (internal) |
Environmental
| Operating temperature | 0–50 ℃ (−40–70 ℃ optional) |
| Storage temperature | −10–60 ℃ |
| Relative humidity | 10%–90%, non-condensing |
| EMC | CE, FCC (EN 55032 & EN 55035), EN IEC 61000-3-2 |
| Factory | ISO 9001:2015 |
| MTBF | 60,000 hours |
Mechanical & compliance
| Dimension | 313.9 (W) × 199.8 (D) × 87 (H) mm |
| Cutout size | 264.9 × 184.0 mm |
| Weight | 2.9 KG G.W. |
| Material | 6063 high-strength aluminium alloy |
| Construction | Aluminium extrusion + sheet metal |
| Mounting | Wall mount / VESA mount |
| Certifications | CE / FCC, according to EN 55032 & EN 55035 |
| ODM | BIOS / Boot on LOGO / OEM |
Drawings
Dimensions, cutout and certifications
Check the cutout against your cabinet door before ordering — the CTN-1262D needs 264.9 × 184.0 mm and 87 mm of depth behind it.


Ordering information
Configurations and part numbers
Each row is a factory build: the build fixes the processor, the memory and the storage. The panel, the touchscreen, the I/O and the cutout are the same for every row.
| NO. | Model | Product Part Number | Description | Standard Memory | Standard Storage |
|---|---|---|---|---|---|
| 1 | CTN-1262D | C11.01.04.014 | Intel® Celeron® J1900 Processor | 4GB | mSATA SSD 128GB |
| 2 | CTN-1262D | C11.01.04.015 | Intel® Celeron® J6412 Processor | 8GB | mSATA SSD 256GB |
| 3 | CTN-1262D | C11.01.04.016 | Intel® Core™ i3-1215U Processor | 8GB | M.2 SSD 256GB |
Contact sales for volume pricing, memory and storage upgrades, the −40–70 ℃ extended temperature build, and 4G / Wi-Fi configuration on the same panel. Rows marked On request are builds whose part number is issued per configuration.
Downloads
CTN-1262D downloads
The full specification is available immediately. Manuals, drivers, certificates and drawings are issued with the quotation.
CTN-1262D datasheet
Panel, touch, I/O, dimensions, cutout and the ordering table (PDF).
Panel PC buying guide
How to size the display, choose the protection rating and specify the cutout.
Industrial PC FAQ
Processor, operating system, mounting and environmental questions.
Manual, drivers & certificates
User manual, driver pack, CE / FCC / BIS certificates, 2D and 3D drawings — issued per order.
FAQ
CTN-1262D frequently asked questions
Questions about the six isolated RS-485 ports, the dry-contact inputs and outputs, the MODBUS interface to a BMS, the 12.5-inch panel and its cutout, and the processor options.
What is the CTN-1262D, and what is it built for?
It is a 12.5-inch industrial panel PC designed for air-conditioning control rooms and environmental monitoring. Instead of a general-purpose port set it carries what those rooms actually use: six isolated RS-485 trunks, four dry-contact inputs, two dry-contact outputs and a MODBUS interface — so one panel polls the plant room and joins the building management system as a node.
Why six RS-485 ports, and why isolated?
Because a plant room is six separate buses, not one. Chillers, air-handling units, VAV boxes, meters, sensors and the BMS gateway each tend to run on their own RS-485 trunk, and merging them means re-addressing equipment that is already commissioned. The panel also carries one isolated RS232 port for the older controller that never moved to a bus, two USB 2.0 ports and audio. Isolation is the second half of the answer: between two buildings or two risers there is often a ground-potential difference, and a non-isolated port is what fails when it appears.
What can the dry-contact inputs and outputs do?
The four inputs read switch-type signals — float switches, fan-proof and filter-differential contacts, door contacts, pump run-status relays. The two outputs drive annunciators, lamps or interlocks. They are wired to terminal blocks on the panel rather than through a separate I/O module, and because the whole set is exposed over MODBUS, the BMS or SCADA master reads and writes them the same way it handles any other node. The block is 4 inputs and 2 outputs, alongside six isolated RS485 ports and one isolated RS232 port.
How does it integrate with an existing BMS or SCADA system?
The panel speaks MODBUS. The existing master polls its registers like any other station and sees the six RS-485 buses and the dry-contact block as data points. Nothing proprietary is involved and the BMS program does not have to be rewritten, which is usually why this panel is bought for a retrofit: the riser cupboard gets a display and an edge controller without touching the head-end configuration.
What display and touchscreen does the 12.5-inch panel use?
A 12.5-inch 16:9 TFT at 1920 × 1080, 300 cd/m² with 500:1 contrast and an LED backlight rated at 50,000 hours. Touch is projected capacitive, with resistive 5-wire available on request, and the front bezel is IP65 — a plant room is a dusty place, and the front can be wiped down without water reaching the electronics.
What are the dimensions, cutout and mounting?
313.9 (W) × 199.8 (D) × 87 (H) mm with a cutout of 264.9 × 184.0 mm, weighing 2.9 kg gross. It mounts in the panel cutout, on a wall bracket or on a VESA plate. Cooling is completely fanless — no filter to clean and no fan to seize in a room that is normally unmanned.
Which processor does the standard build use, and what are the options?
The standard build is the Intel® Celeron® J1900 at 2.0–2.42 GHz with 4–8GB DDR3L and an mSATA SSD (part number C11.01.04.014) — a 10 W part, which is why this model runs cool in a closed cupboard. A Celeron J6412 build with DDR4 (C11.01.04.015) and a 12th Gen Core i3-1215U build with DDR5 and 2× M.2 SSD (C11.01.04.016) are available as platform options in the same cutout; CPU model may vary, so confirm the configuration with sales.
What power, network and environmental ratings does it have?
12V DC on a 3-pin pluggable terminal block, with 9–36V DC optional and an internal AT/ATX mode switch. Networking is 2× Intel I210 Gigabit LAN, with Wi-Fi (Intel N6235) and optional 4G LTE. Operating temperature is 0–50 ℃ as standard with −40–70 ℃ available; storage is −10–60 ℃ and humidity 10%–90% non-condensing.
What certifications and customisation come with the building-automation panel?
CE and FCC according to EN 55032 and EN 55035 plus EN IEC 61000-3-2, from an ISO 9001:2015 factory with MTBF of 60,000 hours. ODM covers custom BIOS, boot-on-LOGO and OEM branding, and because the panel is a BlockCore™ platform the processor tier, the wireless options and the touch type are all set per order.
Related models
Other models in the ODM range
The CTN-1262D is the building-automation panel — six isolated RS485 ports and dry contacts for air-conditioning and environmental monitoring; if you need multiple Intel LAN ports, a battery inside the panel, a SIM card slot, a touch power key or 8DI/8DO GPIO, one of its siblings carries it.
Send us the cutout, the I/O list and the environment
Tell us the panel size and the existing cutout, the networks and serial devices you have to connect, the processor tier and the environment. We will confirm the configuration, the part number, the lead time and the price — typically the same working day.
Request a quotation
Tell us what you need — we will quote your application
Pick the specification and the application below — every answer reaches us as a separate line, so one reply can confirm the exact build, lead time and price. Not sure about a field? Leave it on “advise me” and our engineers will choose for you.